OC 2010 - LSU

SCAN TRONIC

COMBUSTION OPTIMIZING

FOR GREEN NATURE

OC 2010 - LSU / udgået af produktion /

Benefits

 

  • Simple installation and maintenance
  • Rapid reaction (T90 less than 5 seconds)
  • Simple and accurate setting of alarms
  • No pumps or other moving parts
  • Alarm for probe fault
  • Wide band sensor OS2014
  • LSU-cable for connection between sensor and amplifier
  • Offering long service life
  • Simple calibration
  • Attractive design in anodized aluminium

Application

 

  • Measuring of excess oxygen (O2) directly in the flue-gas channel after combustion.

 

  • Measuring the level of oxygen content in protective gases, for instance in connection with packaging of food products. Facilitates regulation and thus minimum consumption of gases.

 

  • Measuring and controlling the consumption of protective gases in connection with welding, for example stainless steel.

Power supply

230 V AC 50/60 Hz

Power consumption

Approx. 30 VA

Dimensions

H x W x D 244 x 159 x 65 mm

Measuring range

0.5 - 20.9% O2

Display

Seven segment L.E.D. display 0.5% O2 - 20.9% O2

Accuracy

± 0.15%

Ambient temperature

0- 60 °C

Output signals

0(4)-20 mA corresponding to 0% O2 - 20,9% O2

Galvanic isolation

300 V DC (OC 2010 only)

Alarms

2 individually set levels 0.5% O2 - 20.9% O2

Heat up time

Approx. 20 seconds

Calibration

Atmospheric air and 1% or 2% O2 in N2 every 6 months

Cable connections

2 pcs. M16 and 1 pc. M20 cable glands

Probe connections

2 pcs. M16 and 1 pc. M20 cable glands